SD

Manufacturer’s information has to be observed strictly (ETA-05/0069). *Permissible load for a single anchor in cracked normal concrete (concrete tension zone) with a consistency of ≥ C20/25

galvanized, according to ISO 4042

Product
Lmin
diameter diameter
t
Pzul
PzulR30
PzulR90
weight
SDK 10/10 55 mm 10 mm 10 mm 0-10 mm 4.30 kN 1.80 kN 1.80 kN 5.88 kg/100
SD 8/10 55 mm 8 mm 8 mm 0 – 10 mm 3.60 kN 1.40 kN 0.90 kN 3.50 kg/100
SD 8/30 55 mm 8 mm 8 mm 0 – 30 mm 3.60 kN 1.40 kN 0.90 kN 4.40 kg/100
SD 10/10 75 mm 10 mm 10 mm 0 – 10 mm 5.70 kN 2.80 kN 1.90 kN 6.20 kg/100
SD 10/30 75 mm 10 mm 10 mm 0 – 30 mm 5.70 kN 2.80 kN 1.90 kN 7.80 kg/100
SD 12/10 90 mm 12 mm 12 mm 0 – 10 mm 9.50 kN 5.00 kN 3.20 kN 11 kg/100
SD 16/25 110 mm 16 mm 16 mm 0 – 25 mm 13.40 kN 9.40 kN 6.00 kN 26.30 kg/100

Stainless steel, according to ASTM 31 Ti / AISI 316 L, BS 320S17 / BS 316S11

Product
Lmin
diameter diameter
t
Pzul
PzulR30
PzulR90
weight
SD 8/10E4 55 mm 8 mm 8 mm 0 – 10 mm 3.60 kN 1.40 kN 0.90 kN 3.60 kg/100
SD 10/10E4 75 mm 10 mm 10 mm 0 – 10 mm 5.70 kN 2.80 kN 1.90 kN 6.20 kg/100
SD 12/10E4 90 mm 12 mm 12 mm 0 – 10 mm 9.50 kN 5.00 kN 3.20 kN 10.90 kg/100


Warning: Uninitialized string offset 0 in /data/1/a/1a84424d-a096-4e7d-8c29-af9e4679dcb1/kabelax.sk/web/wp-includes/class-wp-query.php on line 3766